# ESPHome truma_inetbox component
ESPHome component to remote control Truma CP Plus Heater by simulating a Truma iNet box.
See [1](https://github.com/danielfett/inetbox.py) and [2](https://github.com/mc0110/inetbox2mqtt) for great documentation about how to connect an CP Plus to an ESP32 or RP2040.
## Acknowledgements
This project is based on the work of the [WomoLIN project](https://github.com/muccc/WomoLIN) and [mc0110 inetbox.py](https://github.com/danielfett/inetbox.py), especially the initial protocol decoding and the inet box log files.
## Example configuation
This example is just for connecting ESPHome to the CP Plus. See [truma.yaml](/truma.yaml) for an example config with all possible things configured.
```yaml
esphome:
name: "esphome-truma"
external_components:
- source: github://Fabian-Schmidt/esphome-truma_inetbox
esp32:
board: mhetesp32devkit
uart:
- id: lin_uart_bus
baud_rate: 9600
stop_bits: 2
truma_inetbox:
uart_id: lin_uart_bus
binary_sensor:
- platform: truma_inetbox
name: "CP Plus alive"
type: CP_PLUS_CONNECTED
sensor:
- platform: truma_inetbox
name: "Current Room Temperature"
type: CURRENT_ROOM_TEMPERATURE
- platform: truma_inetbox
name: "Current Water Temperature"
type: CURRENT_WATER_TEMPERATURE
- platform: truma_inetbox
name: "Target Room Temperature"
type: TARGET_ROOM_TEMPERATURE
- platform: truma_inetbox
name: "Target Water Temperature"
type: TARGET_WATER_TEMPERATURE
```
## ESPHome components
This project contains the following ESPHome components:
- `uart` will overwrite the default uart component to expose internal fields.
- `truma_inetbox` has the following settings:
- `cs_pin` (optional) if you connect the pin of your lin driver chip.
- `fault_pin` (optional) if you connect the pin of your lin driver chip.
- `on_heater_message` (optional) [ESPHome Trigger](https://esphome.io/guides/automations.html) when a message from CP Plus is recieved.
### Binary sensor
Binary sensors are read-only.
```yaml
binary_sensor:
- platform: truma_inetbox
name: "CP Plus alive"
type: CP_PLUS_CONNECTED
```
The following `type` values are available:
- `CP_PLUS_CONNECTED`
- `HEATER_ROOM`
- `HEATER_WATER`
- `HEATER_GAS`
- `HEATER_DIESEL`
- `HEATER_MIX_1`
- `HEATER_MIX_2`
- `HEATER_ELECTRICITY`
- `HEATER_HAS_ERROR`
- `TIMER_ACTIVE`
- `TIMER_ROOM`
- `TIMER_WATER`
### Climate
Climate components support read and write.
```yaml
climate:
- platform: truma_inetbox
name: "Truma Room"
type: ROOM
- platform: truma_inetbox
name: "Truma Water"
type: WATER
```
The following `type` values are available:
- `ROOM`
- `WATER`
### Number
Number components support read and write.
```yaml
number:
- platform: truma_inetbox
name: "Target Room Temperature"
type: TARGET_ROOM_TEMPERATURE
```
The following `type` values are available:
- `TARGET_ROOM_TEMPERATURE`
- `TARGET_WATER_TEMPERATURE`
- `ELECTRIC_POWER_LEVEL`
### Sensor
Sensors are read-only.
```yaml
sensor:
- platform: truma_inetbox
name: "Current Room Temperature"
type: CURRENT_ROOM_TEMPERATURE
```
The following `type` values are available:
- `CURRENT_ROOM_TEMPERATURE`
- `CURRENT_WATER_TEMPERATURE`
- `TARGET_ROOM_TEMPERATURE`
- `TARGET_WATER_TEMPERATURE`
- `HEATING_MODE`
- `ELECTRIC_POWER_LEVEL`
- `ENERGY_MIX`
- `OPERATING_STATUS`
- `HEATER_ERROR_CODE`
### Actions
The following [ESP Home actions](https://esphome.io/guides/automations.html#actions) are available:
- `truma_inetbox.heater.set_target_room_temperature`
- `temperature` - Temperature between 5C and 30C. Below 5C will disable the Heater.
- `heating_mode` - Optional set heating mode: `"OFF"`, `ECO`, `HIGH`, `BOOST`.
- `truma_inetbox.heater.set_target_water_temperature`
- `temperature` - Set water temp as number: `0`, `40`, `60`, `80`.
- `truma_inetbox.heater.set_target_water_temperature_enum`
- `temperature` - Set water temp as text: `"OFF"`, `ECO`, `HIGH`, `BOOST`.
- `truma_inetbox.heater.set_electric_power_level`
- `watt` - Set electricity level to `0`, `900`, `1800`.
- `truma_inetbox.heater.set_energy_mix`
- `energy_mix` - Set energy mix to: `GAS`, `MIX`, `ELECTRICITY`.
- `watt` - Optional: Set electricity level to `0`, `900`, `1800`
- `truma_inetbox.timer.disable` - Disable the timer configuration.
- `truma_inetbox.timer.activate` - Set a new timer configuration.
- `start` - Start time.
- `stop` - Stop time.
- `room_temperature` - Temperature between 5C and 30C.
- `heating_mode` - Optional: Set heating mode: `"OFF"`, `ECO`, `HIGH`, `BOOST`.
- `water_temperature` - Optional: Set water temp as number: `0`, `40`, `60`, `80`.
- `energy_mix` - Optional: Set energy mix to: `GAS`, `MIX`, `ELECTRICITY`.
- `watt` - Optional: Set electricity level to `0`, `900`, `1800`.
- `truma_inetbox.clock.set` - Update CP Plus from ESP Home. You *must* have another [clock source](https://esphome.io/#time-components) configured like Home Assistant Time, GPS or DS1307 RTC.
## TODO
- [ ] This file
- [ ] Testing of Combi 4E / Combi 6E and Alde devices (I only have access to an Combi 4)
- [ ] More Testing