2023-04-26 15:50:08 +02:00

258 lines
6.9 KiB
YAML

esphome:
name: "esphome-truma-all-config"
on_boot:
then:
# read time from external source (connected via I2C)
- ds1307.read_time
external_components:
- source: github://Fabian-Schmidt/esphome-truma_inetbox
# - source:
# type: local
# path: ./components
components: ["truma_inetbox"]
esp32:
board: esp32dev
framework:
type: arduino
i2c:
sda: 14
scl: 27
scan: false
id: i2c_bus_a
time:
- platform: ds1307
update_interval: never
id: esptime
uart:
- id: lin_uart_bus
tx_pin: 17
rx_pin: 16
baud_rate: 9600
data_bits: 8
parity: NONE
stop_bits: 2
truma_inetbox:
uart_id: lin_uart_bus
time_id: esptime
cs_pin: 5
fault_pin: 18
# Advanced users can use `on_heater_message` action. The heater data is in the `message` variable.
on_heater_message:
then:
- logger.log: "Message from CP Plus."
- if:
condition:
lambda: return message->operating_status == truma_inetbox::OperatingStatus::OPERATING_STATUS_OFF;
then:
- logger.log: "Heater is off."
binary_sensor:
- platform: truma_inetbox
name: "CP Plus alive"
type: CP_PLUS_CONNECTED
- platform: truma_inetbox
name: "Room Heater active"
type: HEATER_ROOM
id: HEATER_ROOM
- platform: truma_inetbox
name: "Water Heater active"
type: HEATER_WATER
id: HEATER_WATER
- platform: truma_inetbox
name: "Heater mode Gas"
type: HEATER_GAS
- platform: truma_inetbox
name: "Heater mode Mix 1"
type: HEATER_MIX_1
- platform: truma_inetbox
name: "Heater mode Mix 2"
type: HEATER_MIX_2
- platform: truma_inetbox
name: "Heater mode Elec"
type: HEATER_ELECTRICITY
- platform: truma_inetbox
name: "Heater has error"
type: HEATER_HAS_ERROR
- platform: truma_inetbox
name: "Timer active"
type: TIMER_ACTIVE
id: TIMER_ACTIVE
- platform: truma_inetbox
name: "Timer Room Heater active"
type: TIMER_ROOM
- platform: truma_inetbox
name: "Timer Water Heater active"
type: TIMER_WATER
climate:
- platform: truma_inetbox
name: "Truma Room"
type: ROOM
- platform: truma_inetbox
name: "Truma Water"
type: WATER
number:
- platform: truma_inetbox
name: "Target Room Temperature"
type: TARGET_ROOM_TEMPERATURE
- platform: truma_inetbox
name: "Target Water Temperature"
type: TARGET_WATER_TEMPERATURE
- platform: truma_inetbox
name: "electric power level"
type: ELECTRIC_POWER_LEVEL
- platform: truma_inetbox
name: "Aircon Temperature"
type: AIRCON_MANUAL_TEMPERATURE
sensor:
- platform: truma_inetbox
name: "Current Room Temperature"
type: CURRENT_ROOM_TEMPERATURE
- platform: truma_inetbox
name: "Current Water Temperature"
type: CURRENT_WATER_TEMPERATURE
- platform: truma_inetbox
name: "Target Room Temperature"
type: TARGET_ROOM_TEMPERATURE
- platform: truma_inetbox
name: "Target Water Temperature"
type: TARGET_WATER_TEMPERATURE
- platform: truma_inetbox
name: "Heating mode"
type: HEATING_MODE
- platform: truma_inetbox
name: "electric power level"
type: ELECTRIC_POWER_LEVEL
- platform: truma_inetbox
name: "Energy mix"
type: ENERGY_MIX
- platform: truma_inetbox
name: "Operating status"
type: OPERATING_STATUS
- platform: truma_inetbox
name: "Heater error code"
type: HEATER_ERROR_CODE
switch:
- platform: template
name: "Activate Room Heater"
lambda: |-
return id(HEATER_ROOM).state;
turn_on_action:
- truma_inetbox.heater.set_target_room_temperature:
# You can use lambda functions
temperature: !lambda |-
return 16;
# Optional set heating mode: `"OFF"`, `ECO`, `HIGH`, `BOOST`
heating_mode: ECO
turn_off_action:
- truma_inetbox.heater.set_target_room_temperature:
# Disable heater by setting temperature to `0`.
temperature: 0
- platform: template
name: "Activate Water Heater"
lambda: |-
return id(HEATER_WATER).state;
turn_on_action:
- truma_inetbox.heater.set_target_water_temperature:
# Set water temp as number: `0`, `40`, `60`, `80`
temperature: 40
turn_off_action:
- truma_inetbox.heater.set_target_water_temperature:
# Disable heater by setting temperature to `0`.
temperature: 0
- platform: template
name: "Activate Water Heater (enum)"
lambda: |-
return id(HEATER_WATER).state;
turn_on_action:
- truma_inetbox.heater.set_target_water_temperature_enum:
# Set water temp as text: `"OFF"`, `ECO`, `HIGH`, `BOOST`
temperature: ECO
turn_off_action:
# You can also use the simplified syntax.
- truma_inetbox.heater.set_target_water_temperature_enum: "OFF"
- platform: template
name: "Active Timer"
lambda: |-
return id(TIMER_ACTIVE).state;
turn_on_action:
- truma_inetbox.timer.activate:
start: 7:00
stop: 9:30
# Required: Set room temp to a number between 5 and 30
room_temperature: 13
# Optional: Set heating mode: `"OFF"`, `ECO`, `HIGH`, `BOOST`
heating_mode: ECO
# Optional: Set water temp as number: `0`, `40`, `60`, `80`
water_temperature: 0
# Optional: Set energy mix to: `GAS`, `MIX`, `ELECTRICITY`
energy_mix: GAS
# Optional: Set electricity level to `0`, `900`, `1800`
watt: 0
turn_off_action:
# You can also use the simplified syntax.
- truma_inetbox.timer.disable
button:
- platform: template
name: "Energy mix GAS only"
on_press:
- truma_inetbox.heater.set_energy_mix:
# Set energy mix to: `GAS`, `MIX`, `ELECTRICITY`
energy_mix: GAS
- platform: template
name: "Energy mix MIX 1"
on_press:
- truma_inetbox.heater.set_energy_mix:
energy_mix: MIX
# Set electricity level to `0`, `900`, `1800`
watt: 900W
- platform: template
name: "Energy mix MIX 2"
on_press:
- truma_inetbox.heater.set_energy_mix:
energy_mix: MIX
watt: 1800
- platform: template
name: "Energy mix ELECTRICITY only"
on_press:
- truma_inetbox.heater.set_energy_mix:
energy_mix: ELECTRICITY
watt: 1800W
- platform: template
name: "Set electric power level to 0 Watt"
on_press:
- truma_inetbox.heater.set_electric_power_level: 0
- platform: template
name: "Set electric power level to 900 Watt"
on_press:
- truma_inetbox.heater.set_electric_power_level: 900
- platform: template
name: "Set electric power level to 1800 Watt"
on_press:
- truma_inetbox.heater.set_electric_power_level: 1800
wifi:
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Fallback Hotspot"
password: "Sw9g4XJtoyrn"
web_server:
port: 80
local: true
version: 2
include_internal: true