from typing import Optional
|
|
|
|
import esphome.codegen as cg
|
|
import esphome.config_validation as cv
|
|
import esphome.final_validate as fv
|
|
from esphome import pins, automation
|
|
from esphome.components import uart, time
|
|
from esphome.const import (
|
|
CONF_ID,
|
|
CONF_NUMBER,
|
|
CONF_BAUD_RATE,
|
|
CONF_UART_ID,
|
|
CONF_RX_PIN,
|
|
CONF_TX_PIN,
|
|
CONF_INVERTED,
|
|
CONF_CS_PIN,
|
|
CONF_TEMPERATURE,
|
|
CONF_TRIGGER_ID,
|
|
CONF_STOP,
|
|
CONF_TIME_ID,
|
|
|
|
CONF_MASTER_MODE = "master_mode"
|
|
CONF_WRITES_ARMED = "writes_armed"
|
|
CONF_MASTER_NAD = "master_nad")
|
|
from esphome.components.uart import (
|
|
CONF_STOP_BITS,
|
|
CONF_DATA_BITS,
|
|
CONF_PARITY,
|
|
KEY_UART_DEVICES,
|
|
)
|
|
from esphome.core import CORE
|
|
from .entity_helpers import count_id_usage
|
|
|
|
DEPENDENCIES = ["uart"]
|
|
CODEOWNERS = ["@Fabian-Schmidt"]
|
|
|
|
CONF_TRUMA_INETBOX_ID = "truma_inetbox_id"
|
|
CONF_LIN_CHECKSUM = "lin_checksum"
|
|
CONF_FAULT_PIN = "fault_pin"
|
|
CONF_OBSERVER_MODE = "observer_mode"
|
|
CONF_NUMBER_OF_CHILDREN = "number_of_children"
|
|
CONF_ON_HEATER_MESSAGE = "on_heater_message"
|
|
|
|
truma_inetbox_ns = cg.esphome_ns.namespace("truma_inetbox")
|
|
StatusFrameHeater = truma_inetbox_ns.struct("StatusFrameHeater")
|
|
StatusFrameHeaterConstPtr = StatusFrameHeater.operator("ptr").operator("const")
|
|
TrumaINetBoxApp = truma_inetbox_ns.class_(
|
|
"TrumaiNetBoxApp", cg.PollingComponent, uart.UARTDevice
|
|
)
|
|
TrumaiNetBoxAppHeaterMessageTrigger = truma_inetbox_ns.class_(
|
|
"TrumaiNetBoxAppHeaterMessageTrigger",
|
|
automation.Trigger.template(StatusFrameHeaterConstPtr),
|
|
)
|
|
|
|
# `LIN_CHECKSUM` is a enum class and not a namespace but it works.
|
|
LIN_CHECKSUM_dummy_ns = truma_inetbox_ns.namespace("LIN_CHECKSUM")
|
|
|
|
CONF_SUPPORTED_LIN_CHECKSUM = {
|
|
"VERSION_1": LIN_CHECKSUM_dummy_ns.LIN_CHECKSUM_VERSION_1,
|
|
"VERSION_2": LIN_CHECKSUM_dummy_ns.LIN_CHECKSUM_VERSION_2,
|
|
}
|
|
|
|
# [RP2040] Hardware serial of uart validation:
|
|
# constexpr uint32_t valid_tx_uart_0 = __bitset({0, 12, 16, 28});
|
|
# constexpr uint32_t valid_tx_uart_1 = __bitset({4, 8, 20, 24});
|
|
# constexpr uint32_t valid_rx_uart_0 = __bitset({1, 13, 17, 29});
|
|
# constexpr uint32_t valid_rx_uart_1 = __bitset({5, 9, 21, 25});
|
|
CONF_RP2040_HARDWARE_UART = {
|
|
CONF_TX_PIN: {
|
|
# Pin : Hardware UART number
|
|
0: 0,
|
|
12: 0,
|
|
16: 0,
|
|
28: 0,
|
|
4: 1,
|
|
8: 1,
|
|
20: 1,
|
|
24: 1,
|
|
},
|
|
CONF_RX_PIN: {
|
|
# Pin : Hardware UART number
|
|
1: 0,
|
|
13: 0,
|
|
17: 0,
|
|
29: 0,
|
|
5: 1,
|
|
9: 1,
|
|
21: 1,
|
|
25: 1,
|
|
}
|
|
}
|
|
|
|
|
|
def final_validate_device_schema(
|
|
name: str,
|
|
*,
|
|
baud_rate: Optional[int] = None,
|
|
require_tx: bool = False,
|
|
require_rx: bool = False,
|
|
stop_bits: Optional[int] = None,
|
|
data_bits: Optional[int] = None,
|
|
parity: str = None,
|
|
require_hardware_uart: Optional[bool] = None,
|
|
):
|
|
def validate_baud_rate(value):
|
|
if value != baud_rate:
|
|
raise cv.Invalid(
|
|
f"Component {name} required baud rate {baud_rate} for the uart bus"
|
|
)
|
|
return value
|
|
|
|
def validate_pin(opt, device):
|
|
def validator(value):
|
|
if opt in device:
|
|
raise cv.Invalid(
|
|
f"The uart {opt} is used both by {name} and {device[opt]}, "
|
|
f"but can only be used by one. Please create a new uart bus for {name}."
|
|
)
|
|
device[opt] = name
|
|
return value
|
|
|
|
return validator
|
|
|
|
def validate_stop_bits(value):
|
|
if value != stop_bits:
|
|
raise cv.Invalid(
|
|
f"Component {name} required stop bits {stop_bits} for the uart bus"
|
|
)
|
|
return value
|
|
|
|
def validate_data_bits(value):
|
|
if value != data_bits:
|
|
raise cv.Invalid(
|
|
f"Component {name} required data bits {data_bits} for the uart bus"
|
|
)
|
|
return value
|
|
|
|
def validate_parity(value):
|
|
if value != parity:
|
|
raise cv.Invalid(
|
|
f"Component {name} required parity {parity} for the uart bus"
|
|
)
|
|
return value
|
|
|
|
def validate_hardware_uart(opt, opt2=None, declaration_config=None):
|
|
def validator(value):
|
|
if (CORE.is_rp2040):
|
|
if value[CONF_INVERTED]:
|
|
raise cv.Invalid(
|
|
f"Component {name} required Hardware UART. Inverted is not supported by Hardware UART.")
|
|
if value[CONF_NUMBER] not in CONF_RP2040_HARDWARE_UART[opt]:
|
|
raise cv.Invalid(
|
|
f"Component {name} required Hardware UART. {opt} is not a Hardware UART pin.")
|
|
if opt2 and declaration_config and CONF_RP2040_HARDWARE_UART[opt2][declaration_config[opt2][CONF_NUMBER]] != CONF_RP2040_HARDWARE_UART[opt][value[CONF_NUMBER]]:
|
|
raise cv.Invalid(
|
|
f"Component {name} required Hardware UART. {opt} and {opt2} are not a matching Hardware UART pin set.")
|
|
|
|
return value
|
|
return validator
|
|
|
|
def validate_hub(hub_config):
|
|
hub_schema = {}
|
|
uart_id = hub_config[CONF_ID]
|
|
devices = fv.full_config.get().data.setdefault(KEY_UART_DEVICES, {})
|
|
device = devices.setdefault(uart_id, {})
|
|
|
|
if require_tx:
|
|
hub_schema[
|
|
cv.Required(
|
|
CONF_TX_PIN,
|
|
msg=f"Component {name} requires this uart bus to declare a tx_pin",
|
|
)
|
|
] = validate_pin(CONF_TX_PIN, device)
|
|
if require_rx:
|
|
hub_schema[
|
|
cv.Required(
|
|
CONF_RX_PIN,
|
|
msg=f"Component {name} requires this uart bus to declare a rx_pin",
|
|
)
|
|
] = validate_pin(CONF_RX_PIN, device)
|
|
if baud_rate is not None:
|
|
hub_schema[cv.Required(CONF_BAUD_RATE)] = validate_baud_rate
|
|
if stop_bits is not None:
|
|
hub_schema[cv.Required(CONF_STOP_BITS)] = validate_stop_bits
|
|
if data_bits is not None:
|
|
hub_schema[cv.Required(CONF_DATA_BITS)] = validate_data_bits
|
|
if parity is not None:
|
|
hub_schema[cv.Required(CONF_PARITY)] = validate_parity
|
|
if require_hardware_uart is not None:
|
|
fconf = fv.full_config.get()
|
|
path = fconf.get_path_for_id(uart_id)[:-1]
|
|
declaration_config = fconf.get_config_for_path(path)
|
|
hub_schema[cv.Required(CONF_TX_PIN)] = validate_hardware_uart(
|
|
CONF_TX_PIN)
|
|
hub_schema[cv.Required(CONF_RX_PIN)] = validate_hardware_uart(
|
|
CONF_RX_PIN, CONF_TX_PIN, declaration_config)
|
|
return cv.Schema(hub_schema, extra=cv.ALLOW_EXTRA)(hub_config)
|
|
|
|
return cv.Schema(
|
|
{cv.Required(CONF_UART_ID)
|
|
: fv.id_declaration_match_schema(validate_hub)},
|
|
extra=cv.ALLOW_EXTRA,
|
|
)
|
|
|
|
|
|
CONFIG_SCHEMA = cv.All(
|
|
cv.Schema(
|
|
{
|
|
cv.GenerateID(): cv.declare_id(TrumaINetBoxApp),
|
|
cv.Optional(CONF_TIME_ID): cv.use_id(time.RealTimeClock),
|
|
cv.Optional(CONF_LIN_CHECKSUM, "VERSION_2"): cv.enum(CONF_SUPPORTED_LIN_CHECKSUM, upper=True),
|
|
cv.Optional(CONF_CS_PIN): pins.gpio_output_pin_schema,
|
|
cv.Optional(CONF_FAULT_PIN): pins.gpio_input_pin_schema,
|
|
cv.Optional(CONF_OBSERVER_MODE): cv.boolean,
|
|
cv.Optional(CONF_ON_HEATER_MESSAGE): automation.validate_automation(
|
|
{
|
|
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(TrumaiNetBoxAppHeaterMessageTrigger),
|
|
}
|
|
),
|
|
}
|
|
)
|
|
# Polling is for presenting data to sensors.
|
|
# Reading and communication is done in a seperate thread/core.
|
|
.extend(cv.polling_component_schema("500ms"))
|
|
.extend(uart.UART_DEVICE_SCHEMA),
|
|
cv.only_on(["esp32", "rp2040"]),
|
|
)
|
|
FINAL_VALIDATE_SCHEMA = cv.All(
|
|
final_validate_device_schema(
|
|
"truma_inetbox", baud_rate=9600, require_tx=True, require_rx=True, stop_bits=2, data_bits=8, parity="NONE", require_hardware_uart=True),
|
|
)
|
|
|
|
async def to_code(config):
|
|
if CORE.using_esp_idf:
|
|
# Run interrupt on core 0. ESP Home runs on core 1.
|
|
cg.add_build_flag("-DARDUINO_SERIAL_EVENT_TASK_RUNNING_CORE=0")
|
|
# Default Stack Size is 2048. Not enough for my operation.
|
|
cg.add_build_flag("-DARDUINO_SERIAL_EVENT_TASK_STACK_SIZE=4096")
|
|
|
|
var = cg.new_Pvariable(config[CONF_ID])
|
|
await cg.register_component(var, config)
|
|
await uart.register_uart_device(var, config)
|
|
if (CONF_TIME_ID in config):
|
|
time_ = await cg.get_variable(config[CONF_TIME_ID])
|
|
cg.add(var.set_time(time_))
|
|
|
|
if CONF_LIN_CHECKSUM in config:
|
|
cg.add(var.set_lin_checksum(
|
|
CONF_SUPPORTED_LIN_CHECKSUM[config[CONF_LIN_CHECKSUM]]))
|
|
|
|
if CONF_CS_PIN in config:
|
|
pin = await cg.gpio_pin_expression(config[CONF_CS_PIN])
|
|
cg.add(var.set_cs_pin(pin))
|
|
|
|
if CONF_FAULT_PIN in config:
|
|
pin = await cg.gpio_pin_expression(config[CONF_FAULT_PIN])
|
|
cg.add(var.set_fault_pin(pin))
|
|
|
|
if CONF_OBSERVER_MODE in config:
|
|
cg.add(var.set_observer_mode(config[CONF_OBSERVER_MODE]))
|
|
|
|
for conf in config.get(CONF_ON_HEATER_MESSAGE, []):
|
|
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
|
await automation.build_automation(
|
|
trigger, [(StatusFrameHeaterConstPtr, "message")], conf
|
|
)
|
|
|
|
|
|
# AUTOMATION
|
|
|
|
CONF_ENERGY_MIX = "energy_mix"
|
|
CONF_ELECTRIC_POWER_LEVEL = "electric_power_level"
|
|
CONF_HEATING_MODE = "heating_mode"
|
|
CONF_WATT = "watt"
|
|
CONF_START = "start"
|
|
CONF_ROOM_TEMPERATURE = "room_temperature"
|
|
CONF_WATER_TEMPERATURE = "water_temperature"
|
|
|
|
HeaterRoomTempAction = truma_inetbox_ns.class_(
|
|
"HeaterRoomTempAction", automation.Action)
|
|
HeaterWaterTempAction = truma_inetbox_ns.class_(
|
|
"HeaterWaterTempAction", automation.Action)
|
|
HeaterWaterTempEnumAction = truma_inetbox_ns.class_(
|
|
"HeaterWaterTempEnumAction", automation.Action)
|
|
HeaterElecPowerLevelAction = truma_inetbox_ns.class_(
|
|
"HeaterElecPowerLevelAction", automation.Action)
|
|
HeaterEnergyMixAction = truma_inetbox_ns.class_(
|
|
"HeaterEnergyMixAction", automation.Action)
|
|
AirconManualTempAction = truma_inetbox_ns.class_(
|
|
"AirconManualTempAction", automation.Action)
|
|
TimerDisableAction = truma_inetbox_ns.class_(
|
|
"TimerDisableAction", automation.Action)
|
|
TimerActivateAction = truma_inetbox_ns.class_(
|
|
"TimerActivateAction", automation.Action)
|
|
WriteTimeAction = truma_inetbox_ns.class_("WriteTimeAction", automation.Action)
|
|
|
|
# `EnergyMix` is a enum class and not a namespace but it works.
|
|
EnergyMix_dummy_ns = truma_inetbox_ns.namespace("EnergyMix")
|
|
|
|
CONF_SUPPORTED_ENERGY_MIX = {
|
|
"NONE": EnergyMix_dummy_ns.ENERGY_MIX_NONE,
|
|
"GAS": EnergyMix_dummy_ns.ENERGY_MIX_GAS,
|
|
"DIESEL": EnergyMix_dummy_ns.ENERGY_MIX_DIESEL,
|
|
"ELECTRICITY": EnergyMix_dummy_ns.ENERGY_MIX_ELECTRICITY,
|
|
"MIX": EnergyMix_dummy_ns.ENERGY_MIX_MIX,
|
|
}
|
|
|
|
# `ElectricPowerLevel` is a enum class and not a namespace but it works.
|
|
ElectricPowerLevel_dummy_ns = truma_inetbox_ns.namespace("ElectricPowerLevel")
|
|
|
|
CONF_SUPPORTED_ELECTRIC_POWER_LEVEL = {
|
|
"0": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_0,
|
|
"0W": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_0,
|
|
"0 W": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_0,
|
|
"900": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_900,
|
|
"900W": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_900,
|
|
"900 W": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_900,
|
|
"1800": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_1800,
|
|
"1800W": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_1800,
|
|
"1800 W": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_1800,
|
|
"1.8kW": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_1800,
|
|
"1,8kW": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_1800,
|
|
"1.8 kW": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_1800,
|
|
"1,8 kW": ElectricPowerLevel_dummy_ns.ELECTRIC_POWER_LEVEL_1800,
|
|
}
|
|
|
|
# `HeatingMode` is a enum class and not a namespace but it works.
|
|
HeatingMode_dummy_ns = truma_inetbox_ns.namespace("HeatingMode")
|
|
|
|
CONF_SUPPORTED_HEATING_MODE = {
|
|
"OFF": HeatingMode_dummy_ns.HEATING_MODE_OFF,
|
|
"ECO": HeatingMode_dummy_ns.HEATING_MODE_ECO,
|
|
"NIGHT": HeatingMode_dummy_ns.HEATING_MODE_VARIO_HEAT_NIGHT,
|
|
"AUTO": HeatingMode_dummy_ns.HEATING_MODE_VARIO_HEAT_AUTO,
|
|
"HIGH": HeatingMode_dummy_ns.HEATING_MODE_HIGH,
|
|
"BOOST": HeatingMode_dummy_ns.HEATING_MODE_BOOST,
|
|
}
|
|
|
|
# `TargetTemp` is a enum class and not a namespace but it works.
|
|
TargetTemp_dummy_ns = truma_inetbox_ns.namespace("TargetTemp")
|
|
|
|
CONF_SUPPORTED_WATER_TEMPERATURE = {
|
|
"OFF": TargetTemp_dummy_ns.TARGET_TEMP_OFF,
|
|
"ECO": TargetTemp_dummy_ns.TARGET_TEMP_WATER_ECO,
|
|
"HIGH": TargetTemp_dummy_ns.TARGET_TEMP_WATER_HIGH,
|
|
"BOOST": TargetTemp_dummy_ns.TARGET_TEMP_WATER_BOOST,
|
|
}
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.heater.set_target_room_temperature",
|
|
HeaterRoomTempAction,
|
|
automation.maybe_conf(
|
|
CONF_TEMPERATURE,
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_TEMPERATURE): cv.templatable(cv.int_range(min=0, max=30)),
|
|
cv.Optional(CONF_HEATING_MODE, "OFF"): cv.templatable(cv.enum(CONF_SUPPORTED_HEATING_MODE, upper=True)),
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_heater_set_target_room_temperature_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
|
|
template_ = await cg.templatable(config[CONF_TEMPERATURE], args, cg.uint8)
|
|
cg.add(var.set_temperature(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_HEATING_MODE], args, cg.uint16)
|
|
cg.add(var.set_heating_mode(template_))
|
|
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.heater.set_target_water_temperature",
|
|
HeaterWaterTempAction,
|
|
automation.maybe_conf(
|
|
CONF_TEMPERATURE,
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_TEMPERATURE): cv.templatable(cv.int_range(min=0, max=80)),
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_heater_set_target_water_temperature_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
|
|
template_ = await cg.templatable(config[CONF_TEMPERATURE], args, cg.uint8)
|
|
cg.add(var.set_temperature(template_))
|
|
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.heater.set_target_water_temperature_enum",
|
|
HeaterWaterTempEnumAction,
|
|
automation.maybe_conf(
|
|
CONF_TEMPERATURE,
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_TEMPERATURE): cv.templatable(cv.enum(CONF_SUPPORTED_WATER_TEMPERATURE, upper=True))
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_heater_set_target_water_temperature_enum_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
|
|
template_ = await cg.templatable(config[CONF_TEMPERATURE], args, cg.uint16)
|
|
cg.add(var.set_temperature(template_))
|
|
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.heater.set_electric_power_level",
|
|
HeaterElecPowerLevelAction,
|
|
automation.maybe_conf(
|
|
CONF_WATT,
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_WATT): cv.templatable(cv.int_range(min=0, max=1800))
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_heater_set_electric_power_level_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
|
|
template_ = await cg.templatable(config[CONF_WATT], args, cg.uint16)
|
|
cg.add(var.set_watt(template_))
|
|
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.heater.set_energy_mix",
|
|
HeaterEnergyMixAction,
|
|
cv.Schema(
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_ENERGY_MIX): cv.templatable(cv.enum(CONF_SUPPORTED_ENERGY_MIX, upper=True)),
|
|
cv.Optional(CONF_WATT, 0): cv.templatable(cv.enum(CONF_SUPPORTED_ELECTRIC_POWER_LEVEL, upper=True)),
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_heater_set_energy_mix_level_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
|
|
template_ = await cg.templatable(config[CONF_ENERGY_MIX], args, cg.uint8)
|
|
cg.add(var.set_energy_mix(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_WATT], args, cg.uint16)
|
|
cg.add(var.set_watt(template_))
|
|
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.aircon.manual.set_target_temperature",
|
|
AirconManualTempAction,
|
|
automation.maybe_conf(
|
|
CONF_TEMPERATURE,
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_TEMPERATURE): cv.templatable(cv.int_range(min=0, max=31)),
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_aircon_manual_set_target_temperature_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
|
|
template_ = await cg.templatable(config[CONF_TEMPERATURE], args, cg.uint8)
|
|
cg.add(var.set_temperature(template_))
|
|
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.timer.disable",
|
|
TimerDisableAction,
|
|
automation.maybe_simple_id(
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_timer_disable_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.timer.activate",
|
|
TimerActivateAction,
|
|
automation.maybe_simple_id(
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_START): cv.templatable(cv.int_range(min=0, max=1440)),
|
|
cv.Required(CONF_STOP): cv.templatable(cv.int_range(min=0, max=1440)),
|
|
cv.Required(CONF_ROOM_TEMPERATURE): cv.templatable(cv.int_range(min=0, max=30)),
|
|
cv.Optional(CONF_HEATING_MODE, "OFF"): cv.templatable(cv.enum(CONF_SUPPORTED_HEATING_MODE, upper=True)),
|
|
cv.Optional(CONF_WATER_TEMPERATURE, 0): cv.templatable(cv.int_range(min=0, max=80)),
|
|
cv.Optional(CONF_ENERGY_MIX, "NONE"): cv.templatable(cv.enum(CONF_SUPPORTED_ENERGY_MIX, upper=True)),
|
|
cv.Optional(CONF_WATT, 0): cv.templatable(cv.enum(CONF_SUPPORTED_ELECTRIC_POWER_LEVEL, upper=True)),
|
|
|
|
}
|
|
),
|
|
)
|
|
async def truma_inetbox_timer_activate_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
|
|
template_ = await cg.templatable(config[CONF_START], args, cg.uint16)
|
|
cg.add(var.set_start(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_STOP], args, cg.uint16)
|
|
cg.add(var.set_stop(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_ROOM_TEMPERATURE], args, cg.uint8)
|
|
cg.add(var.set_room_temperature(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_HEATING_MODE], args, cg.uint16)
|
|
cg.add(var.set_heating_mode(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_WATER_TEMPERATURE], args, cg.uint8)
|
|
cg.add(var.set_water_temperature(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_ENERGY_MIX], args, cg.uint8)
|
|
cg.add(var.set_energy_mix(template_))
|
|
|
|
template_ = await cg.templatable(config[CONF_WATT], args, cg.uint16)
|
|
cg.add(var.set_watt(template_))
|
|
return var
|
|
|
|
|
|
@automation.register_action(
|
|
"truma_inetbox.clock.set",
|
|
WriteTimeAction,
|
|
automation.maybe_simple_id(
|
|
{
|
|
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
|
},
|
|
cv.requires_component(CONF_TIME),
|
|
),
|
|
)
|
|
async def truma_inetbox_clock_set_to_code(config, action_id, template_arg, args):
|
|
var = cg.new_Pvariable(action_id, template_arg)
|
|
await cg.register_parented(var, config[CONF_ID])
|
|
return var
|