84 lines
3.4 KiB
Python
84 lines
3.4 KiB
Python
from esphome.components import sensor
|
|
import esphome.config_validation as cv
|
|
import esphome.codegen as cg
|
|
from esphome.const import (
|
|
CONF_ID,
|
|
CONF_TYPE,
|
|
DEVICE_CLASS_TEMPERATURE,
|
|
CONF_UNIT_OF_MEASUREMENT,
|
|
UNIT_CELSIUS,
|
|
CONF_ICON,
|
|
ICON_THERMOMETER,
|
|
STATE_CLASS_MEASUREMENT,
|
|
CONF_ACCURACY_DECIMALS,
|
|
CONF_DEVICE_CLASS,
|
|
UNIT_WATT,
|
|
UNIT_EMPTY,
|
|
ICON_GAS_CYLINDER,
|
|
ICON_POWER,
|
|
)
|
|
from .. import truma_inetbox_ns, CONF_TRUMA_INETBOX_ID, TrumaINetBoxApp
|
|
|
|
DEPENDENCIES = ["truma_inetbox"]
|
|
CODEOWNERS = ["@Fabian-Schmidt"]
|
|
|
|
TrumaSensor = truma_inetbox_ns.class_(
|
|
"TrumaSensor", sensor.Sensor, cg.Component)
|
|
|
|
# `TRUMA_SENSOR_TYPE` is a enum class and not a namespace but it works.
|
|
TRUMA_SENSOR_TYPE_dummy_ns = truma_inetbox_ns.namespace("TRUMA_SENSOR_TYPE")
|
|
|
|
# 0 - C++ enum
|
|
# 1 - CONF_UNIT_OF_MEASUREMENT
|
|
# 2 - CONF_ICON
|
|
# 3 - CONF_ACCURACY_DECIMALS
|
|
# 4 - CONF_DEVICE_CLASS
|
|
CONF_SUPPORTED_TYPE = {
|
|
"CURRENT_ROOM_TEMPERATURE": (TRUMA_SENSOR_TYPE_dummy_ns.CURRENT_ROOM_TEMPERATURE, UNIT_CELSIUS, ICON_THERMOMETER, 1, DEVICE_CLASS_TEMPERATURE),
|
|
"CURRENT_WATER_TEMPERATURE": (TRUMA_SENSOR_TYPE_dummy_ns.CURRENT_WATER_TEMPERATURE, UNIT_CELSIUS, ICON_THERMOMETER, 1, DEVICE_CLASS_TEMPERATURE),
|
|
"TARGET_ROOM_TEMPERATURE": (TRUMA_SENSOR_TYPE_dummy_ns.TARGET_ROOM_TEMPERATURE, UNIT_CELSIUS, ICON_THERMOMETER, 0, DEVICE_CLASS_TEMPERATURE),
|
|
"TARGET_WATER_TEMPERATURE": (TRUMA_SENSOR_TYPE_dummy_ns.TARGET_WATER_TEMPERATURE, UNIT_CELSIUS, ICON_THERMOMETER, 0, DEVICE_CLASS_TEMPERATURE),
|
|
"HEATING_MODE": (TRUMA_SENSOR_TYPE_dummy_ns.HEATING_MODE, UNIT_EMPTY, ICON_THERMOMETER, 0, DEVICE_CLASS_TEMPERATURE),
|
|
"ELECTRIC_POWER_LEVEL": (TRUMA_SENSOR_TYPE_dummy_ns.ELECTRIC_POWER_LEVEL, UNIT_WATT, ICON_POWER, 0, DEVICE_CLASS_TEMPERATURE),
|
|
"ENERGY_MIX": (TRUMA_SENSOR_TYPE_dummy_ns.ENERGY_MIX, UNIT_EMPTY, ICON_GAS_CYLINDER, 0, DEVICE_CLASS_TEMPERATURE),
|
|
"OPERATING_STATUS": (TRUMA_SENSOR_TYPE_dummy_ns.OPERATING_STATUS, UNIT_EMPTY, ICON_POWER, 0, DEVICE_CLASS_TEMPERATURE),
|
|
"HEATER_ERROR_CODE": (TRUMA_SENSOR_TYPE_dummy_ns.HEATER_ERROR_CODE, UNIT_EMPTY, ICON_POWER, 0, DEVICE_CLASS_TEMPERATURE),
|
|
}
|
|
|
|
|
|
def set_default_based_on_type():
|
|
def set_defaults_(config):
|
|
# set defaults based on sensor type:
|
|
if CONF_UNIT_OF_MEASUREMENT not in config:
|
|
config[CONF_UNIT_OF_MEASUREMENT] = CONF_SUPPORTED_TYPE[config[CONF_TYPE]][1]
|
|
if CONF_ICON not in config:
|
|
config[CONF_ICON] = CONF_SUPPORTED_TYPE[config[CONF_TYPE]][2]
|
|
if CONF_ACCURACY_DECIMALS not in config:
|
|
config[CONF_ACCURACY_DECIMALS] = CONF_SUPPORTED_TYPE[config[CONF_TYPE]][3]
|
|
if CONF_DEVICE_CLASS not in config:
|
|
config[CONF_DEVICE_CLASS] = CONF_SUPPORTED_TYPE[config[CONF_TYPE]][4]
|
|
return config
|
|
|
|
return set_defaults_
|
|
|
|
|
|
CONFIG_SCHEMA = sensor.sensor_schema(
|
|
state_class=STATE_CLASS_MEASUREMENT
|
|
).extend(
|
|
{
|
|
cv.GenerateID(): cv.declare_id(TrumaSensor),
|
|
cv.GenerateID(CONF_TRUMA_INETBOX_ID): cv.use_id(TrumaINetBoxApp),
|
|
cv.Required(CONF_TYPE): cv.enum(CONF_SUPPORTED_TYPE, upper=True),
|
|
}
|
|
).extend(cv.COMPONENT_SCHEMA)
|
|
FINAL_VALIDATE_SCHEMA = set_default_based_on_type()
|
|
|
|
|
|
async def to_code(config):
|
|
var = cg.new_Pvariable(config[CONF_ID])
|
|
await cg.register_component(var, config)
|
|
await sensor.register_sensor(var, config)
|
|
await cg.register_parented(var, config[CONF_TRUMA_INETBOX_ID])
|
|
|
|
cg.add(var.set_type(CONF_SUPPORTED_TYPE[config[CONF_TYPE]][0]))
|