2023-03-22 20:13:42 +01:00

50 lines
2.1 KiB
C++

#include "TrumaHeaterBinarySensor.h"
#include "esphome/core/log.h"
#include "esphome/components/truma_inetbox/helpers.h"
namespace esphome {
namespace truma_inetbox {
static const char *const TAG = "truma_inetbox.heater_binary_sensor";
void TrumaHeaterBinarySensor::setup() {
this->parent_->get_heater()->add_on_message_callback([this](const StatusFrameHeater *status_heater) {
switch (this->type_) {
case TRUMA_BINARY_SENSOR_TYPE::HEATER_ROOM:
this->publish_state(status_heater->target_temp_room != TargetTemp::TARGET_TEMP_OFF);
break;
case TRUMA_BINARY_SENSOR_TYPE::HEATER_WATER:
this->publish_state(status_heater->target_temp_water != TargetTemp::TARGET_TEMP_OFF);
break;
case TRUMA_BINARY_SENSOR_TYPE::HEATER_GAS:
this->publish_state(status_heater->energy_mix_a == EnergyMix::ENERGY_MIX_GAS);
break;
case TRUMA_BINARY_SENSOR_TYPE::HEATER_DIESEL:
this->publish_state(status_heater->energy_mix_a == EnergyMix::ENERGY_MIX_DIESEL);
break;
case TRUMA_BINARY_SENSOR_TYPE::HEATER_MIX_1:
this->publish_state(status_heater->energy_mix_a == EnergyMix::ENERGY_MIX_MIX &&
status_heater->el_power_level_a == ElectricPowerLevel::ELECTRIC_POWER_LEVEL_900);
break;
case TRUMA_BINARY_SENSOR_TYPE::HEATER_MIX_2:
this->publish_state(status_heater->energy_mix_a == EnergyMix::ENERGY_MIX_MIX &&
status_heater->el_power_level_a == ElectricPowerLevel::ELECTRIC_POWER_LEVEL_1800);
break;
case TRUMA_BINARY_SENSOR_TYPE::HEATER_ELECTRICITY:
this->publish_state(status_heater->energy_mix_a == EnergyMix::ENERGY_MIX_ELECTRICITY);
break;
case TRUMA_BINARY_SENSOR_TYPE::HEATER_HAS_ERROR:
this->publish_state(status_heater->error_code_high != 0x00);
break;
default:
break;
}
});
}
void TrumaHeaterBinarySensor::dump_config() {
LOG_BINARY_SENSOR("", "Truma Heater Binary Sensor", this);
ESP_LOGCONFIG(TAG, " Type '%s'", enum_to_c_str(this->type_));
}
} // namespace truma_inetbox
} // namespace esphome