testing support for Vario Heater
This commit is contained in:
parent
10d8385a30
commit
aaf95e79d4
@ -195,11 +195,11 @@ bool TrumaiNetBoxApp::lin_read_field_by_identifier_(u_int8_t identifier, std::ar
|
||||
(*response)[1] = lin_identifier[1];
|
||||
(*response)[2] = lin_identifier[2];
|
||||
(*response)[3] = lin_identifier[3];
|
||||
(*response)[4] = 0x01; // Hardware revision
|
||||
(*response)[4] = 0x01; // Variant
|
||||
return true;
|
||||
} else if (identifier == 0x20 /* Product details to display in CP plus */) {
|
||||
auto lin_identifier = this->lin_identifier();
|
||||
// Only the first three parts are used.
|
||||
// Only the first three parts are displayed.
|
||||
(*response)[0] = lin_identifier[0];
|
||||
(*response)[1] = lin_identifier[1];
|
||||
(*response)[2] = lin_identifier[2];
|
||||
@ -322,7 +322,7 @@ const u_int8_t *TrumaiNetBoxApp::lin_multiframe_recieved(const u_int8_t *message
|
||||
|
||||
this->update_status_timer_stale_ = false;
|
||||
|
||||
ESP_LOGV(TAG, "StatusFrameTimer target_temp_room: %f target_temp_water: %f %u:%u -> %u:%u %s",
|
||||
ESP_LOGD(TAG, "StatusFrameTimer target_temp_room: %f target_temp_water: %f %u:%u -> %u:%u %s",
|
||||
temp_code_to_decimal(this->status_timer_.timer_target_temp_room),
|
||||
temp_code_to_decimal(this->status_timer_.timer_target_temp_water), this->status_timer_.timer_start_hours,
|
||||
this->status_timer_.timer_start_minutes, this->status_timer_.timer_stop_hours,
|
||||
@ -341,7 +341,7 @@ const u_int8_t *TrumaiNetBoxApp::lin_multiframe_recieved(const u_int8_t *message
|
||||
} else {
|
||||
ESP_LOGI(TAG, "StatusFrameResponseAck");
|
||||
}
|
||||
ESP_LOGV(TAG, "StatusFrameResponseAck %02X %s %02X", statusFrame->inner.genericHeader.command_counter,
|
||||
ESP_LOGD(TAG, "StatusFrameResponseAck %02X %s %02X", statusFrame->inner.genericHeader.command_counter,
|
||||
data.error_code == ResponseAckResult::RESPONSE_ACK_RESULT_OKAY ? " OKAY " : " FAILED ",
|
||||
(u_int8_t) data.error_code);
|
||||
|
||||
@ -362,7 +362,7 @@ const u_int8_t *TrumaiNetBoxApp::lin_multiframe_recieved(const u_int8_t *message
|
||||
this->status_clock_valid_ = true;
|
||||
this->status_clock_updated_ = true;
|
||||
|
||||
ESP_LOGV(TAG, "StatusFrameClock %02d:%02d:%02d", this->status_clock_.clock_hour, this->status_clock_.clock_minute,
|
||||
ESP_LOGD(TAG, "StatusFrameClock %02d:%02d:%02d", this->status_clock_.clock_hour, this->status_clock_.clock_minute,
|
||||
this->status_clock_.clock_second);
|
||||
|
||||
return response;
|
||||
@ -377,7 +377,7 @@ const u_int8_t *TrumaiNetBoxApp::lin_multiframe_recieved(const u_int8_t *message
|
||||
this->status_config_valid_ = true;
|
||||
this->status_config_updated_ = true;
|
||||
|
||||
ESP_LOGV(TAG, "StatusFrameConfig Offset: %d", offset_code_to_decimal(this->status_config_.temp_offset));
|
||||
ESP_LOGD(TAG, "StatusFrameConfig Offset: %d", offset_code_to_decimal(this->status_config_.temp_offset));
|
||||
|
||||
return response;
|
||||
} else if (header->message_type == STATUS_FRAME_DEVICES && header->message_length == sizeof(StatusFrameDevice)) {
|
||||
@ -385,15 +385,47 @@ const u_int8_t *TrumaiNetBoxApp::lin_multiframe_recieved(const u_int8_t *message
|
||||
// This message is special. I recieve one response per registered (at CP plus) device.
|
||||
// Example:
|
||||
// SID<---------PREAMBLE---------->|<---MSG_HEAD---->|
|
||||
// Combi4
|
||||
// BB.00.1F.00.1E.00.00.22.FF.FF.FF.54.01.0C.0B.00.79.02.00.01.00.50.00.00.04.03.02.AD.10 - C4.03.02 0050.00
|
||||
// BB.00.1F.00.1E.00.00.22.FF.FF.FF.54.01.0C.0B.00.27.02.01.01.00.40.03.22.02.00.01.00.00 - H2.00.01 0340.22
|
||||
// VarioHeat Comfort w/o E-Kit
|
||||
// BB.00.1F.00.1E.00.00.22.FF.FF.FF.54.01.0C.0B.00.C2.02.00.01.00.51.00.00.05.01.00.66.10 - P5.01.00 0051.00
|
||||
// BB.00.1F.00.1E.00.00.22.FF.FF.FF.54.01.0C.0B.00.64.02.01.01.00.20.06.02.03.00.00.00.00 - H3.00.00 0620.02
|
||||
|
||||
auto device = statusFrame->inner.device;
|
||||
|
||||
this->init_recieved_ = micros();
|
||||
|
||||
ESP_LOGV(TAG, "StatusFrameDevice %d/%d - %d.%02d.%02d %04X.%02X", device.device_id + 1, device.device_count,
|
||||
device.software_revision[0], device.software_revision[1], device.software_revision[2],
|
||||
device.hardware_revision_major, device.hardware_revision_minor);
|
||||
ESP_LOGD(TAG, "StatusFrameDevice %d/%d - %d.%02d.%02d %04X.%02X (%02X %02X)", device.device_id + 1,
|
||||
device.device_count, device.software_revision[0], device.software_revision[1], device.software_revision[2],
|
||||
device.hardware_revision_major, device.hardware_revision_minor, device.unkown_2, device.unkown_3);
|
||||
|
||||
{
|
||||
bool found_unkown_value = false;
|
||||
if (device.unkown_0 != 0x01 || device.unkown_1 != 0x00)
|
||||
found_unkown_value = true;
|
||||
if (device.software_revision[0] != TRUMA_DEVICE::HEATER_COMBI &&
|
||||
device.software_revision[0] != TRUMA_DEVICE::HEATER_VARIO &&
|
||||
device.software_revision[0] != TRUMA_DEVICE::CPPLUS_COMBI &&
|
||||
device.software_revision[0] != TRUMA_DEVICE::CPPLUS_VARIO)
|
||||
found_unkown_value = true;
|
||||
if (device.unkown_2 != 0xAD && device.unkown_2 != 0x66 && device.unkown_2 != 0x00)
|
||||
found_unkown_value = true;
|
||||
if (device.unkown_3 != 0x10 && device.unkown_3 != 0x00)
|
||||
found_unkown_value = true;
|
||||
|
||||
if (found_unkown_value)
|
||||
ESP_LOGW(TAG, "Unkown information in StatusFrameDevice found. Please report.");
|
||||
}
|
||||
|
||||
// Assumption device id one is always the heater.
|
||||
if (device.device_id == 1) {
|
||||
if (device.software_revision[0] == TRUMA_DEVICE::HEATER_COMBI) {
|
||||
this->heater_device_ = TRUMA_DEVICE::HEATER_COMBI;
|
||||
} else if (device.software_revision[0] == TRUMA_DEVICE::HEATER_VARIO) {
|
||||
this->heater_device_ = TRUMA_DEVICE::HEATER_VARIO;
|
||||
}
|
||||
}
|
||||
|
||||
return response;
|
||||
} else {
|
||||
|
||||
@ -45,8 +45,15 @@ namespace truma_inetbox {
|
||||
|
||||
enum class HeatingMode : u_int16_t {
|
||||
HEATING_MODE_OFF = 0x0,
|
||||
// COMBI
|
||||
HEATING_MODE_ECO = 0x1,
|
||||
// Vario Heat
|
||||
HEATING_MODE_VARIO_HEAT_NIGHT = 0x2,
|
||||
// Vario Heat
|
||||
HEATING_MODE_VARIO_HEAT_AUTO = 0x3,
|
||||
// COMBI
|
||||
HEATING_MODE_HIGH = 0xA,
|
||||
// COMBI, Vario Heat
|
||||
HEATING_MODE_BOOST = 0xB,
|
||||
|
||||
// Feedback Invalid message only with following `heating_mode`. Others are ignored no feedback.
|
||||
@ -297,6 +304,14 @@ struct StatusFrameConfig { // NOLINT(altera-struct-pack-align)
|
||||
u_int8_t unkown_8;
|
||||
} __attribute__((packed));
|
||||
|
||||
enum class TRUMA_DEVICE : u_int8_t {
|
||||
UNKOWN = 0x00,
|
||||
HEATER_COMBI = 0x02,
|
||||
HEATER_VARIO = 0x03,
|
||||
CPPLUS_COMBI = 0x04,
|
||||
CPPLUS_VARIO = 0x05,
|
||||
};
|
||||
|
||||
// Length 12 (0x0C)
|
||||
struct StatusFrameDevice { // NOLINT(altera-struct-pack-align)
|
||||
u_int8_t device_count;
|
||||
@ -308,12 +323,13 @@ struct StatusFrameDevice { // NOLINT(altera-struct-pack-align)
|
||||
u_int16_t hardware_revision_major;
|
||||
u_int8_t hardware_revision_minor;
|
||||
// `software_revision[0].software_revision[1].software_revision[2]`
|
||||
// software_revision[0] -> TRUMA_DEVICE
|
||||
u_int8_t software_revision[3];
|
||||
// 0xAD on CPplus
|
||||
// 0x00 on Combi4
|
||||
// 0xAD on CPplus with Combi4 or 0x66 on CPplus with Vario Heat Comfort ohne E
|
||||
// 0x00 on Combi4, Vario Heat
|
||||
u_int8_t unkown_2;
|
||||
// 0x10 on CPplus
|
||||
// 0x00 on Combi4
|
||||
// 0x00 on Combi4, Vario Heat
|
||||
u_int8_t unkown_3;
|
||||
|
||||
} __attribute__((packed));
|
||||
@ -417,6 +433,9 @@ class TrumaiNetBoxApp : public LinBusProtocol {
|
||||
uint32_t init_recieved_ = 0;
|
||||
u_int8_t message_counter = 1;
|
||||
|
||||
// Truma heater conected to CP Plus.
|
||||
TRUMA_DEVICE heater_device_ = TRUMA_DEVICE::HEATER_COMBI;
|
||||
|
||||
std::vector<StatusFrameListener> listeners_heater_;
|
||||
CallbackManager<void(const StatusFrameHeater *)> state_heater_callback_{};
|
||||
|
||||
|
||||
@ -22,6 +22,16 @@ bool TrumaiNetBoxApp::action_heater_room(u_int8_t temperature, HeatingMode mode)
|
||||
if (heater->target_temp_room == TargetTemp::TARGET_TEMP_OFF) {
|
||||
heater->heating_mode = HeatingMode::HEATING_MODE_OFF;
|
||||
} else {
|
||||
if (this->heater_device_ == TRUMA_DEVICE::HEATER_VARIO) {
|
||||
// If parameter `mode` contains a valid Heating mode use it or else use `AUTO`.
|
||||
if (mode == HeatingMode::HEATING_MODE_VARIO_HEAT_NIGHT || mode == HeatingMode::HEATING_MODE_VARIO_HEAT_AUTO ||
|
||||
mode == HeatingMode::HEATING_MODE_BOOST) {
|
||||
heater->heating_mode = mode;
|
||||
} else if (heater->heating_mode == HeatingMode::HEATING_MODE_OFF) {
|
||||
heater->heating_mode = HeatingMode::HEATING_MODE_VARIO_HEAT_AUTO;
|
||||
}
|
||||
} else {
|
||||
// HEATER_COMBI
|
||||
// If parameter `mode` contains a valid Heating mode use it or else use `ECO`.
|
||||
if (mode == HeatingMode::HEATING_MODE_ECO || mode == HeatingMode::HEATING_MODE_HIGH ||
|
||||
mode == HeatingMode::HEATING_MODE_BOOST) {
|
||||
@ -30,6 +40,7 @@ bool TrumaiNetBoxApp::action_heater_room(u_int8_t temperature, HeatingMode mode)
|
||||
heater->heating_mode = HeatingMode::HEATING_MODE_ECO;
|
||||
}
|
||||
}
|
||||
}
|
||||
if (heater->energy_mix_a == EnergyMix::ENERGY_MIX_NONE) {
|
||||
heater->energy_mix_a = EnergyMix::ENERGY_MIX_GAS;
|
||||
}
|
||||
@ -178,6 +189,16 @@ bool TrumaiNetBoxApp::action_timer_activate(u_int16_t start, u_int16_t stop, u_i
|
||||
if (timer->timer_target_temp_room == TargetTemp::TARGET_TEMP_OFF) {
|
||||
timer->timer_heating_mode = HeatingMode::HEATING_MODE_OFF;
|
||||
} else {
|
||||
if (this->heater_device_ == TRUMA_DEVICE::HEATER_VARIO) {
|
||||
// If parameter `mode` contains a valid Heating mode use it or else use `AUTO`.
|
||||
if (mode == HeatingMode::HEATING_MODE_VARIO_HEAT_NIGHT || mode == HeatingMode::HEATING_MODE_VARIO_HEAT_AUTO ||
|
||||
mode == HeatingMode::HEATING_MODE_BOOST) {
|
||||
timer->timer_heating_mode = mode;
|
||||
} else if (timer->timer_heating_mode == HeatingMode::HEATING_MODE_OFF) {
|
||||
timer->timer_heating_mode = HeatingMode::HEATING_MODE_VARIO_HEAT_AUTO;
|
||||
}
|
||||
} else {
|
||||
// HEATER_COMBI
|
||||
// If parameter `mode` contains a valid Heating mode use it or else use `ECO`.
|
||||
if (mode == HeatingMode::HEATING_MODE_ECO || mode == HeatingMode::HEATING_MODE_HIGH ||
|
||||
mode == HeatingMode::HEATING_MODE_BOOST) {
|
||||
@ -186,6 +207,7 @@ bool TrumaiNetBoxApp::action_timer_activate(u_int16_t start, u_int16_t stop, u_i
|
||||
timer->timer_heating_mode = HeatingMode::HEATING_MODE_ECO;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
timer->timer_target_temp_water = deciaml_to_water_temp(water_temperature);
|
||||
|
||||
|
||||
@ -327,6 +327,8 @@ HeatingMode_dummy_ns = truma_inetbox_ns.namespace("HeatingMode")
|
||||
CONF_SUPPORTED_HEATING_MODE = {
|
||||
"OFF": HeatingMode_dummy_ns.HEATING_MODE_OFF,
|
||||
"ECO": HeatingMode_dummy_ns.HEATING_MODE_ECO,
|
||||
"NIGHT": HeatingMode_dummy_ns.HEATING_MODE_VARIO_HEAT_NIGHT,
|
||||
"AUTO": HeatingMode_dummy_ns.HEATING_MODE_VARIO_HEAT_AUTO,
|
||||
"HIGH": HeatingMode_dummy_ns.HEATING_MODE_HIGH,
|
||||
"BOOST": HeatingMode_dummy_ns.HEATING_MODE_BOOST,
|
||||
}
|
||||
|
||||
Loading…