@ -121,6 +121,7 @@ The following `type` values are available:
|
||||
- `TARGET_ROOM_TEMPERATURE`
|
||||
- `TARGET_WATER_TEMPERATURE`
|
||||
- `ELECTRIC_POWER_LEVEL`
|
||||
- `AIRCON_MANUAL_TEMPERATURE`
|
||||
|
||||
### Sensor
|
||||
|
||||
@ -161,6 +162,8 @@ The following [ESP Home actions](https://esphome.io/guides/automations.html#acti
|
||||
- `truma_inetbox.heater.set_energy_mix`
|
||||
- `energy_mix` - Set energy mix to: `GAS`, `MIX`, `ELECTRICITY`.
|
||||
- `watt` - Optional: Set electricity level to `0`, `900`, `1800`
|
||||
- `truma_inetbox.aircon.manual.set_target_temperature`
|
||||
- `temperature` - Temperature between 16C and 31C. Below 16C will disable the Aircon.
|
||||
- `truma_inetbox.timer.disable` - Disable the timer configuration.
|
||||
- `truma_inetbox.timer.activate` - Set a new timer configuration.
|
||||
- `start` - Start time.
|
||||
|
||||
@ -18,7 +18,7 @@ class TrumaStausFrameResponseStorage : public TrumaStausFrameStorage<T>, public
|
||||
this->update_status_unsubmitted_ = false;
|
||||
this->update_status_stale_ = false;
|
||||
}
|
||||
bool can_update() { return this->data_valid_; }
|
||||
virtual bool can_update() { return this->data_valid_; }
|
||||
virtual TResponse *update_prepare() = 0;
|
||||
void update_submit() { this->update_status_unsubmitted_ = true; }
|
||||
const bool has_update() const { return this->update_status_unsubmitted_; }
|
||||
|
||||
@ -2,6 +2,7 @@
|
||||
#include "TrumaStatusFrameBuilder.h"
|
||||
#include "esphome/core/log.h"
|
||||
#include "helpers.h"
|
||||
#include "TrumaiNetBoxApp.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
@ -25,8 +26,8 @@ StatusFrameAirconAutoResponse *TrumaiNetBoxAppAirconAuto::update_prepare() {
|
||||
return &this->update_status_;
|
||||
}
|
||||
|
||||
void TrumaiNetBoxAppAirconAuto::create_update_data(StatusFrame *response, u_int8_t *response_len, u_int8_t command_counter){
|
||||
|
||||
void TrumaiNetBoxAppAirconAuto::create_update_data(StatusFrame *response, u_int8_t *response_len,
|
||||
u_int8_t command_counter) {
|
||||
status_frame_create_empty(response, STATUS_FRAME_AIRCON_AUTO_RESPONSE, sizeof(StatusFrameAirconAutoResponse),
|
||||
command_counter);
|
||||
|
||||
@ -38,10 +39,15 @@ void TrumaiNetBoxAppAirconAuto::create_update_data(StatusFrame *response, u_int8
|
||||
|
||||
status_frame_calculate_checksum(response);
|
||||
(*response_len) = sizeof(StatusFrameHeader) + sizeof(StatusFrameAirconAutoResponse);
|
||||
TrumaStausFrameResponseStorage<StatusFrameAirconAuto, StatusFrameAirconAutoResponse>::update_submitted();
|
||||
TrumaStausFrameResponseStorage<StatusFrameAirconAuto, StatusFrameAirconAutoResponse>::update_submitted();
|
||||
}
|
||||
|
||||
void TrumaiNetBoxAppAirconAuto::dump_data() const {}
|
||||
|
||||
bool TrumaiNetBoxAppAirconAuto::can_update() {
|
||||
return TrumaStausFrameResponseStorage<StatusFrameAirconAuto, StatusFrameAirconAutoResponse>::can_update() &&
|
||||
this->parent_->get_aircon_device() != TRUMA_DEVICE::UNKNOWN;
|
||||
}
|
||||
|
||||
} // namespace truma_inetbox
|
||||
} // namespace esphome
|
||||
@ -12,6 +12,7 @@ class TrumaiNetBoxAppAirconAuto
|
||||
StatusFrameAirconAutoResponse *update_prepare() override;
|
||||
void create_update_data(StatusFrame *response, u_int8_t *response_len, u_int8_t command_counter) override;
|
||||
void dump_data() const override;
|
||||
bool can_update() override;
|
||||
};
|
||||
|
||||
} // namespace truma_inetbox
|
||||
|
||||
@ -2,6 +2,7 @@
|
||||
#include "TrumaStatusFrameBuilder.h"
|
||||
#include "esphome/core/log.h"
|
||||
#include "helpers.h"
|
||||
#include "TrumaiNetBoxApp.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
@ -26,7 +27,7 @@ StatusFrameAirconManualResponse *TrumaiNetBoxAppAirconManual::update_prepare() {
|
||||
}
|
||||
|
||||
void TrumaiNetBoxAppAirconManual::create_update_data(StatusFrame *response, u_int8_t *response_len,
|
||||
u_int8_t command_counter) {
|
||||
u_int8_t command_counter) {
|
||||
status_frame_create_empty(response, STATUS_FRAME_AIRCON_MANUAL_RESPONSE, sizeof(StatusFrameAirconManualResponse),
|
||||
command_counter);
|
||||
|
||||
@ -44,5 +45,24 @@ void TrumaiNetBoxAppAirconManual::create_update_data(StatusFrame *response, u_in
|
||||
|
||||
void TrumaiNetBoxAppAirconManual::dump_data() const {}
|
||||
|
||||
bool TrumaiNetBoxAppAirconManual::can_update() {
|
||||
return TrumaStausFrameResponseStorage<StatusFrameAirconManual, StatusFrameAirconManualResponse>::can_update() &&
|
||||
this->parent_->get_aircon_device() != TRUMA_DEVICE::UNKNOWN;
|
||||
}
|
||||
|
||||
bool TrumaiNetBoxAppAirconManual::action_set_temp(u_int8_t temperature) {
|
||||
if (!this->can_update()) {
|
||||
ESP_LOGW(TAG, "Cannot update Truma.");
|
||||
return false;
|
||||
}
|
||||
|
||||
auto update_data = this->update_prepare();
|
||||
|
||||
update_data->target_temp_aircon = decimal_to_aircon_temp(temperature);
|
||||
|
||||
this->update_submit();
|
||||
return true;
|
||||
}
|
||||
|
||||
} // namespace truma_inetbox
|
||||
} // namespace esphome
|
||||
@ -12,6 +12,9 @@ class TrumaiNetBoxAppAirconManual
|
||||
StatusFrameAirconManualResponse *update_prepare() override;
|
||||
void create_update_data(StatusFrame *response, u_int8_t *response_len, u_int8_t command_counter) override;
|
||||
void dump_data() const override;
|
||||
bool can_update() override;
|
||||
|
||||
bool action_set_temp(u_int8_t temperature);
|
||||
};
|
||||
|
||||
} // namespace truma_inetbox
|
||||
|
||||
@ -49,6 +49,11 @@ void TrumaiNetBoxAppHeater::create_update_data(StatusFrame *response, u_int8_t *
|
||||
|
||||
void TrumaiNetBoxAppHeater::dump_data() const {}
|
||||
|
||||
bool TrumaiNetBoxAppHeater::can_update() {
|
||||
return TrumaStausFrameResponseStorage<StatusFrameHeater, StatusFrameHeaterResponse>::can_update() &&
|
||||
this->parent_->get_heater_device() != TRUMA_DEVICE::UNKNOWN;
|
||||
}
|
||||
|
||||
bool TrumaiNetBoxAppHeater::action_heater_room(u_int8_t temperature, HeatingMode mode) {
|
||||
if (!this->can_update()) {
|
||||
ESP_LOGW(TAG, "Cannot update Truma.");
|
||||
|
||||
@ -11,6 +11,7 @@ class TrumaiNetBoxAppHeater : public TrumaStausFrameResponseStorage<StatusFrameH
|
||||
StatusFrameHeaterResponse *update_prepare() override;
|
||||
void create_update_data(StatusFrame *response, u_int8_t *response_len, u_int8_t command_counter) override;
|
||||
void dump_data() const override;
|
||||
bool can_update() override;
|
||||
|
||||
bool action_heater_room(u_int8_t temperature, HeatingMode mode = HeatingMode::HEATING_MODE_OFF);
|
||||
bool action_heater_water(u_int8_t temperature);
|
||||
|
||||
@ -284,6 +284,8 @@ HeaterElecPowerLevelAction = truma_inetbox_ns.class_(
|
||||
"HeaterElecPowerLevelAction", automation.Action)
|
||||
HeaterEnergyMixAction = truma_inetbox_ns.class_(
|
||||
"HeaterEnergyMixAction", automation.Action)
|
||||
AirconManualTempAction = truma_inetbox_ns.class_(
|
||||
"AirconManualTempAction", automation.Action)
|
||||
TimerDisableAction = truma_inetbox_ns.class_(
|
||||
"TimerDisableAction", automation.Action)
|
||||
TimerActivateAction = truma_inetbox_ns.class_(
|
||||
@ -455,6 +457,27 @@ async def truma_inetbox_heater_set_energy_mix_level_to_code(config, action_id, t
|
||||
return var
|
||||
|
||||
|
||||
@automation.register_action(
|
||||
"truma_inetbox.aircon.manual.set_target_temperature",
|
||||
AirconManualTempAction,
|
||||
automation.maybe_conf(
|
||||
CONF_TEMPERATURE,
|
||||
{
|
||||
cv.GenerateID(): cv.use_id(TrumaINetBoxApp),
|
||||
cv.Required(CONF_TEMPERATURE): cv.templatable(cv.int_range(min=0, max=31)),
|
||||
}
|
||||
),
|
||||
)
|
||||
async def truma_inetbox_aircon_manual_set_target_temperature_to_code(config, action_id, template_arg, args):
|
||||
var = cg.new_Pvariable(action_id, template_arg)
|
||||
await cg.register_parented(var, config[CONF_ID])
|
||||
|
||||
template_ = await cg.templatable(config[CONF_TEMPERATURE], args, cg.uint8)
|
||||
cg.add(var.set_temperature(template_))
|
||||
|
||||
return var
|
||||
|
||||
|
||||
@automation.register_action(
|
||||
"truma_inetbox.timer.disable",
|
||||
TimerDisableAction,
|
||||
|
||||
@ -56,6 +56,15 @@ template<typename... Ts> class HeaterEnergyMixAction : public Action<Ts...>, pub
|
||||
}
|
||||
};
|
||||
|
||||
template<typename... Ts> class AirconManualTempAction : public Action<Ts...>, public Parented<TrumaiNetBoxApp> {
|
||||
public:
|
||||
TEMPLATABLE_VALUE(u_int8_t, temperature)
|
||||
|
||||
void play(Ts... x) override {
|
||||
this->parent_->get_aircon_manual()->action_set_temp(this->temperature_.value_or(x..., 0));
|
||||
}
|
||||
};
|
||||
|
||||
template<typename... Ts> class TimerDisableAction : public Action<Ts...>, public Parented<TrumaiNetBoxApp> {
|
||||
public:
|
||||
void play(Ts... x) override { this->parent_->get_timer()->action_timer_disable(); }
|
||||
|
||||
@ -4,6 +4,8 @@ namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
|
||||
enum class TRUMA_BINARY_SENSOR_TYPE {
|
||||
UNKNOWN,
|
||||
|
||||
HEATER_ROOM,
|
||||
HEATER_WATER,
|
||||
HEATER_GAS,
|
||||
|
||||
@ -38,7 +38,7 @@ TargetTemp decimal_to_room_temp(u_int8_t val) {
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val <= 5) {
|
||||
return TargetTemp::TARGET_TEMP_ROOM_MIN;
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val >= 30) {
|
||||
return TargetTemp::TARGET_TEMP_ROOM_MAX;
|
||||
@ -51,7 +51,7 @@ TargetTemp decimal_to_room_temp(float val) {
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val <= 5) {
|
||||
return TargetTemp::TARGET_TEMP_ROOM_MIN;
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val >= 30) {
|
||||
return TargetTemp::TARGET_TEMP_ROOM_MAX;
|
||||
@ -64,7 +64,7 @@ TargetTemp decimal_to_aircon_temp(u_int8_t val) {
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val <= 16) {
|
||||
return TargetTemp::TARGET_TEMP_AIRCON_MIN;
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val >= 31) {
|
||||
return TargetTemp::TARGET_TEMP_AIRCON_MAX;
|
||||
@ -77,7 +77,7 @@ TargetTemp decimal_to_aircon_temp(float val) {
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val <= 16) {
|
||||
return TargetTemp::TARGET_TEMP_AIRCON_MIN;
|
||||
return TargetTemp::TARGET_TEMP_OFF;
|
||||
}
|
||||
if (val >= 31) {
|
||||
return TargetTemp::TARGET_TEMP_AIRCON_MAX;
|
||||
|
||||
37
components/truma_inetbox/number/TrumaAirconManualNumber.cpp
Normal file
37
components/truma_inetbox/number/TrumaAirconManualNumber.cpp
Normal file
@ -0,0 +1,37 @@
|
||||
#include "TrumaAirconManualNumber.h"
|
||||
#include "esphome/core/log.h"
|
||||
#include "esphome/components/truma_inetbox/helpers.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
|
||||
static const char *const TAG = "truma_inetbox.aircon_manual_number";
|
||||
|
||||
void TrumaAirconManualNumber::setup() {
|
||||
this->parent_->get_aircon_manual()->add_on_message_callback([this](const StatusFrameAirconManual *status) {
|
||||
switch (this->type_) {
|
||||
case TRUMA_NUMBER_TYPE::AIRCON_MANUAL_TEMPERATURE:
|
||||
this->publish_state(temp_code_to_decimal(status->target_temp_aircon, 0));
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
});
|
||||
}
|
||||
|
||||
void TrumaAirconManualNumber::control(float value) {
|
||||
switch (this->type_) {
|
||||
case TRUMA_NUMBER_TYPE::AIRCON_MANUAL_TEMPERATURE:
|
||||
this->parent_->get_aircon_manual()->action_set_temp(static_cast<u_int8_t>(value));
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
void TrumaAirconManualNumber::dump_config() {
|
||||
LOG_NUMBER("", "Truma Aircon Manual Number", this);
|
||||
ESP_LOGCONFIG(TAG, " Type '%s'", enum_to_c_str(this->type_));
|
||||
}
|
||||
} // namespace truma_inetbox
|
||||
} // namespace esphome
|
||||
26
components/truma_inetbox/number/TrumaAirconManualNumber.h
Normal file
26
components/truma_inetbox/number/TrumaAirconManualNumber.h
Normal file
@ -0,0 +1,26 @@
|
||||
#pragma once
|
||||
|
||||
#include "enum.h"
|
||||
#include "esphome/components/number/number.h"
|
||||
#include "esphome/components/truma_inetbox/TrumaiNetBoxApp.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
|
||||
|
||||
class TrumaAirconManualNumber : public Component, public number::Number, public Parented<TrumaiNetBoxApp> {
|
||||
public:
|
||||
void setup() override;
|
||||
void dump_config() override;
|
||||
|
||||
void set_type(TRUMA_NUMBER_TYPE val) { this->type_ = val; }
|
||||
|
||||
protected:
|
||||
TRUMA_NUMBER_TYPE type_;
|
||||
|
||||
void control(float value) override;
|
||||
|
||||
private:
|
||||
};
|
||||
} // namespace truma_inetbox
|
||||
} // namespace esphome
|
||||
@ -19,6 +19,8 @@ void TrumaHeaterNumber::setup() {
|
||||
case TRUMA_NUMBER_TYPE::ELECTRIC_POWER_LEVEL:
|
||||
this->publish_state(static_cast<float>(status_heater->el_power_level_a));
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
});
|
||||
}
|
||||
@ -34,6 +36,8 @@ void TrumaHeaterNumber::control(float value) {
|
||||
case TRUMA_NUMBER_TYPE::ELECTRIC_POWER_LEVEL:
|
||||
this->parent_->get_heater()->action_heater_electric_power_level(static_cast<u_int16_t>(value));
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
@ -1,34 +1,12 @@
|
||||
#pragma once
|
||||
|
||||
#include "enum.h"
|
||||
#include "esphome/components/number/number.h"
|
||||
#include "esphome/components/truma_inetbox/TrumaiNetBoxApp.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
|
||||
enum class TRUMA_NUMBER_TYPE {
|
||||
TARGET_ROOM_TEMPERATURE,
|
||||
TARGET_WATER_TEMPERATURE,
|
||||
ELECTRIC_POWER_LEVEL,
|
||||
};
|
||||
|
||||
static const char *enum_to_c_str(const TRUMA_NUMBER_TYPE val) {
|
||||
switch (val) {
|
||||
case TRUMA_NUMBER_TYPE::TARGET_ROOM_TEMPERATURE:
|
||||
return "TARGET_ROOM_TEMPERATURE";
|
||||
break;
|
||||
case TRUMA_NUMBER_TYPE::TARGET_WATER_TEMPERATURE:
|
||||
return "TARGET_WATER_TEMPERATURE";
|
||||
break;
|
||||
case TRUMA_NUMBER_TYPE::ELECTRIC_POWER_LEVEL:
|
||||
return "ELECTRIC_POWER_LEVEL";
|
||||
break;
|
||||
default:
|
||||
return "";
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
class TrumaHeaterNumber : public Component, public number::Number, public Parented<TrumaiNetBoxApp> {
|
||||
public:
|
||||
void setup() override;
|
||||
|
||||
@ -62,6 +62,18 @@ CONF_SUPPORTED_TYPE = {
|
||||
CONF_MIN_VALUE: 0,
|
||||
CONF_STEP: 900,
|
||||
},
|
||||
|
||||
"AIRCON_MANUAL_TEMPERATURE": {
|
||||
CONF_CLASS: truma_inetbox_ns.class_("TrumaAirconManualNumber", number.Number, cg.Component),
|
||||
CONF_TYPE: TRUMA_NUMBER_TYPE_dummy_ns.AIRCON_MANUAL_TEMPERATURE,
|
||||
CONF_UNIT_OF_MEASUREMENT: UNIT_CELSIUS,
|
||||
CONF_ICON: ICON_THERMOMETER,
|
||||
CONF_DEVICE_CLASS: DEVICE_CLASS_TEMPERATURE,
|
||||
CONF_MAX_VALUE: 31,
|
||||
# Values between 0 and 16 are handeld as off.
|
||||
CONF_MIN_VALUE: 15,
|
||||
CONF_STEP: 1,
|
||||
},
|
||||
}
|
||||
|
||||
|
||||
|
||||
39
components/truma_inetbox/number/enum.h
Normal file
39
components/truma_inetbox/number/enum.h
Normal file
@ -0,0 +1,39 @@
|
||||
#pragma once
|
||||
|
||||
namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
|
||||
enum class TRUMA_NUMBER_TYPE {
|
||||
UNKNOWN,
|
||||
|
||||
TARGET_ROOM_TEMPERATURE,
|
||||
TARGET_WATER_TEMPERATURE,
|
||||
ELECTRIC_POWER_LEVEL,
|
||||
|
||||
AIRCON_MANUAL_TEMPERATURE,
|
||||
};
|
||||
|
||||
static const char *enum_to_c_str(const TRUMA_NUMBER_TYPE val) {
|
||||
switch (val) {
|
||||
case TRUMA_NUMBER_TYPE::TARGET_ROOM_TEMPERATURE:
|
||||
return "TARGET_ROOM_TEMPERATURE";
|
||||
break;
|
||||
case TRUMA_NUMBER_TYPE::TARGET_WATER_TEMPERATURE:
|
||||
return "TARGET_WATER_TEMPERATURE";
|
||||
break;
|
||||
case TRUMA_NUMBER_TYPE::ELECTRIC_POWER_LEVEL:
|
||||
return "ELECTRIC_POWER_LEVEL";
|
||||
break;
|
||||
|
||||
case TRUMA_NUMBER_TYPE::AIRCON_MANUAL_TEMPERATURE:
|
||||
return "AIRCON_MANUAL_TEMPERATURE";
|
||||
break;
|
||||
|
||||
default:
|
||||
return "";
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
} // namespace truma_inetbox
|
||||
} // namespace esphome
|
||||
@ -6,6 +6,7 @@
|
||||
namespace esphome {
|
||||
namespace truma_inetbox {
|
||||
enum class TRUMA_SENSOR_TYPE {
|
||||
UNKNOWN,
|
||||
CURRENT_ROOM_TEMPERATURE,
|
||||
CURRENT_WATER_TEMPERATURE,
|
||||
TARGET_ROOM_TEMPERATURE,
|
||||
|
||||
@ -35,3 +35,13 @@
|
||||
name: "Set electric power level to 1800 Watt"
|
||||
on_press:
|
||||
- truma_inetbox.heater.set_electric_power_level: 1800
|
||||
- platform: template
|
||||
name: "Switch Aircon off"
|
||||
on_press:
|
||||
- truma_inetbox.aircon.manual.set_target_temperature: 0
|
||||
- platform: template
|
||||
name: "Set Aircon to fixed 21 C"
|
||||
on_press:
|
||||
- truma_inetbox.aircon.manual.set_target_temperature: 21
|
||||
|
||||
|
||||
|
||||
@ -7,3 +7,8 @@
|
||||
- platform: truma_inetbox
|
||||
name: "electric power level"
|
||||
type: ELECTRIC_POWER_LEVEL
|
||||
|
||||
- platform: truma_inetbox
|
||||
name: "Aircon manual temp"
|
||||
type: AIRCON_MANUAL_TEMPERATURE
|
||||
|
||||
|
||||